Determine Tread Run and Total Run — Measure the Total Run
Part of project
How to Measure and Plan Treads for a Split-Level Staircase · Step 4 of 8
In this video
The speaker explains that his pre-manufactured stair treads are 11 1/2 inches wide. After deducting 1 inch for nosing (the overhang), the effective run for each tread is 10 1/2 inches. Multiplying this individual tread run (10 1/2 inches) by the 13 treads previously calculated gives a total run of 136 1/2 inches. This total run determines the horizontal space needed for the staircase.
75K subscribers
FAQs
Are all the tools listed necessary for just measuring and planning the staircase treads, or are some for later construction?
For the measuring and planning phase, the essential tools are a 25 ft. tape measure, level, pencil, and a construction calculator (like the Construction Master 5). Items such as the architect ruler can assist in sketching, but materials like tile or vent pipe flashing are intended for the actual construction and finishing phases of the staircase.
How important is verifying local building codes for staircase dimensions, and what happens if I don't?
Verifying local building codes is absolutely critical for safety, comfort, and legality. Codes dictate minimum and maximum riser heights, tread depths, and other dimensions to prevent trip hazards and ensure a safe ascent/descent. Ignoring them can lead to unsafe stairs, failed inspections, and potential liability issues if someone is injured.
What is the most common mistake beginners make when measuring for staircase treads, and how can I avoid it?
A common mistake is an inaccurate initial 'total rise' measurement. Even small errors here will compound over multiple steps, leading to uneven or non-compliant individual riser heights. To avoid this, use a level to ensure your measurement from the finished floor below to the finished floor above is precise, and double-check your numbers multiple times.
Does planning treads for a split-level staircase require any special considerations compared to a straight staircase?
Yes, a split-level staircase often involves multiple flights, landings, or turns, which can complicate the 'total run' measurement and overall layout. You must accurately measure and plan each individual flight and any intermediate landings separately, ensuring that each section adheres to building code requirements for rise, run, and headroom.
TranscriptHide
Auto-generated transcript. May contain errors.
Determine Tread Run and Total Run — Measure the Total Run
Part of project
How to Measure and Plan Treads for a Split-Level Staircase · Step 4 of 8
In this video
The speaker explains that his pre-manufactured stair treads are 11 1/2 inches wide. After deducting 1 inch for nosing (the overhang), the effective run for each tread is 10 1/2 inches. Multiplying this individual tread run (10 1/2 inches) by the 13 treads previously calculated gives a total run of 136 1/2 inches. This total run determines the horizontal space needed for the staircase.
Frequently Asked Questions
Are all the tools listed necessary for just measuring and planning the staircase treads, or are some for later construction?
For the measuring and planning phase, the essential tools are a 25 ft. tape measure, level, pencil, and a construction calculator (like the Construction Master 5). Items such as the architect ruler can assist in sketching, but materials like tile or vent pipe flashing are intended for the actual construction and finishing phases of the staircase.
How important is verifying local building codes for staircase dimensions, and what happens if I don't?
Verifying local building codes is absolutely critical for safety, comfort, and legality. Codes dictate minimum and maximum riser heights, tread depths, and other dimensions to prevent trip hazards and ensure a safe ascent/descent. Ignoring them can lead to unsafe stairs, failed inspections, and potential liability issues if someone is injured.
What is the most common mistake beginners make when measuring for staircase treads, and how can I avoid it?
A common mistake is an inaccurate initial 'total rise' measurement. Even small errors here will compound over multiple steps, leading to uneven or non-compliant individual riser heights. To avoid this, use a level to ensure your measurement from the finished floor below to the finished floor above is precise, and double-check your numbers multiple times.
Does planning treads for a split-level staircase require any special considerations compared to a straight staircase?
Yes, a split-level staircase often involves multiple flights, landings, or turns, which can complicate the 'total run' measurement and overall layout. You must accurately measure and plan each individual flight and any intermediate landings separately, ensuring that each section adheres to building code requirements for rise, run, and headroom.