Calculate Individual Riser Height & Identify Problems — Calculate the Actual Riser Height

Beginner4 hours

Part of project

How to Measure and Plan Treads for a Split-Level Staircase · Step 3 of 8

Helpful?

In this video

Using the total rise (105 inches), the video demonstrates calculating individual riser heights. If dividing 105 inches by 14 risers, each riser would be 7.5 inches, which is acceptable for most codes. However, if a designer attempts to fit 105 inches into 13 risers, each riser would be 8.076 inches. If the maximum allowed riser height is 8 inches, this calculated riser height would be 0.076 inches too high per riser, accumulating to almost a full inch off over the entire staircase (0.076 * 13 = 0.988 inches). This discrepancy, resulting from rounding, can cause code violations or an unsafe staircase. It emphasizes the need to be precise and not round off numbers prematurely.

726 views17
stairbuilding

75K subscribers

View Channel

FAQs

Are all the tools listed necessary for just measuring and planning the staircase treads, or are some for later construction?

For the measuring and planning phase, the essential tools are a 25 ft. tape measure, level, pencil, and a construction calculator (like the Construction Master 5). Items such as the architect ruler can assist in sketching, but materials like tile or vent pipe flashing are intended for the actual construction and finishing phases of the staircase.

How important is verifying local building codes for staircase dimensions, and what happens if I don't?

Verifying local building codes is absolutely critical for safety, comfort, and legality. Codes dictate minimum and maximum riser heights, tread depths, and other dimensions to prevent trip hazards and ensure a safe ascent/descent. Ignoring them can lead to unsafe stairs, failed inspections, and potential liability issues if someone is injured.

What is the most common mistake beginners make when measuring for staircase treads, and how can I avoid it?

A common mistake is an inaccurate initial 'total rise' measurement. Even small errors here will compound over multiple steps, leading to uneven or non-compliant individual riser heights. To avoid this, use a level to ensure your measurement from the finished floor below to the finished floor above is precise, and double-check your numbers multiple times.

Does planning treads for a split-level staircase require any special considerations compared to a straight staircase?

Yes, a split-level staircase often involves multiple flights, landings, or turns, which can complicate the 'total run' measurement and overall layout. You must accurately measure and plan each individual flight and any intermediate landings separately, ensuring that each section adheres to building code requirements for rise, run, and headroom.

Transcript
Hide

105 inches or 8 foot 9 inches. Then to figure out the individual riser height for our stairway with 14 risers, we're simply going to divide 14 into 105 inches. And that gives us a 7.5, a 7 and 1.5 inch riser height, which would be acceptable for most building codes in buildings with less than 50 occupants. But if the minimum riser measurement is 8 inches and the building designer thinks they can get away with 13 risers because when they divide 13 into 105 inches, they get 8.076 inches. And if they want to round that number off to the nearest inch, that's going to be 8 inches. And this is where the problem starts. And yes, I've had this happen to me plenty of times when I was building stairs for large track home builders who needed to make these measurements work even when they didn't. Now for those of you who understand enough about math can figure out that if we multiply 0.076 times 13, we're going to end up with 0.98 or almost 1 inch. However, whether or not that would be a problem or not, I believe it up to you. I just wanted to make you aware of it as a home builder contractor or someone who's going to be assembling the stairs for measurements that are on the plants, suggesting that the individual risers are too close to the maximum rise required by your local building codes.

Auto-generated transcript. May contain errors.