Skip to main content

Visual Assessment of the Array (Modules, Wiring, Mounting) — Assess Solar Panel Condition

Beginner3 hours

Part of project

Solar Panel Cleaning · Step 1 of 6

Helpful?

In this video

Perform a thorough visual inspection of the solar array itself. This involves walking down each row (or every other row depending on configuration) to check both the faces of the modules and underneath them. Look for any damage to modules or wiring caused by vermin or weather. Inspect wire management for frayed wires or unsecured cabling. Ground connections should be checked for loose bolts, nuts, and connectors. Examine mounting systems, module frames, and enclosures for signs of corrosion. Look for blackened or burnt-out cells on modules and assess for dirt or dust accumulation, especially areas where static charge might be leaking voltage. For roof-mounted systems, remove wind deflectors to inspect underneath modules for issues. For ground-mounted systems, check for erosion, excessive vegetation growth around the array, and any corrosion or damage to the mounting structure. For roof-mounted systems, specifically look for algae, water damming, dirt collection, or vegetation growth on the roof surface under the modules. For attached systems (e.g., conduit and wiring on a roof), check for cracks in rubber boots and inspect junction boxes (J-boxes). If necessary, open J-boxes to check internal connections, look for water or vermin intrusion, loose connections, broken terminal blocks, soot marks, or any burning smells. Throughout this process, take numerous pictures and meticulously fill out the field report to document all observations and potential issues.

42.7K views516
Chemical Guys

1.1M subscribers

View Channel

FAQs

What are the most important safety precautions to take when cleaning solar panels?

Always wear safety glasses to protect your eyes. If working at any height, use a stable step ladder and ensure it's on a level surface. Be extremely cautious when working with water near electrical components; never spray directly into wiring, and ensure panels are cool to the touch to prevent thermal shock.

What kind of cleaning solution should I use, and what should I avoid to prevent panel damage?

Use only a mild, non-abrasive cleaning solution, like a small amount of dish soap mixed with deionized or distilled water. Avoid harsh detergents, abrasive cleaners, or high-pressure washers, as these can scratch the panel surface, damage the anti-reflective coating, or compromise seals.

How often should I clean my solar panels, and what's the best time of day to do it?

The frequency depends on your environment, but typically 1-2 times a year is sufficient. The best time to clean is on a cool, overcast morning or late afternoon. This prevents rapid drying of the water, which can leave mineral deposits and water spots on the panels.

Do I need special tools for cleaning solar panels, or can I use a standard garden hose and brush?

While a standard garden hose is a good start, specialized tools like a soft scrub brush with an extendable pole (e.g., Unger 10 ft. Steel Telescoping Pole) and a squeegee (e.g., Ettore 16 in. All-Purpose Squeegee) are highly recommended. These tools help you reach panels safely and clean effectively without scratching them.

Transcript
Hide

issues before starting their overall assessment when assessing the array crew walks down each row or every other row depending on the configuration they look under the modules on one side and the faces of the module modules on the other side they check for damage to modules or wires from varmints and weather they check wire management and look for frayed wires ground connections will be checked for loose bolts nuts and connectors in addition grounding IM bonding locations as well as mounting systems the module frames and enclosures will be checked for corrosion the crew will also look for blackened or burnt out cells in modules dirt or dust might also be collecting on the module duster pollen might collect on a single cell on a module from static charge around a cell that is leaking voltage performance killing dirt or dust might also be collecting on the modules they will remove wind deflectors to look under modules in a large array unless given a specific reason to look at one individual module the crew will choose modules randomly instead of looking at each and every one for a ground mounted system they are looking for erosion and vegetation growth as well as any corrosion or damage to the mounting system on a roof mounted system they're looking for algae water damning dirt collection or vegetation growth on the surface of the roof the crew will also be looking for any space where the racking system might be harming the Integrity of the roof for a ballasted racking system this might be a slip sheet or a pad under the ballast or pads sinking into the roof on an attached system cracks and rubber boots should be noted as well the crew will also check out the junction boxes and might take the covers off and look at the connections inside they'll also look for water buildup and varmits later test may send a crew back to revisit any of these areas throughout this process the crews take lots of pictures and fill out the field report after completing the visual assessment of the array Crews may go back and close up any J boxes that they have left

Auto-generated transcript. May contain errors.

Visual Assessment of the Array (Modules, Wiring, Mounting) — Solar Panel Cleaning (Step 1, Video 3) | Stesso