Proceed with wiring the outdoor unit and the quick disconnect box. Use a suitable connector (e.g., from a previous project heat treating oven) to ensure a watertight connection for the cables running from the indoor unit to the outdoor condenser. Open the outdoor unit's electrical panel. The outdoor unit's wiring is also labeled on the panel: connect the green ground wire to the green ground screw on the left, the yellow wire to port number one, the white wire to port number two, and the black wire to port number three. For the main power side, the creator used a pre-made 6-foot, 10 American Wire Gauge (AWG) whip. Verify that the 20 amp breaker (from Step 1) is turned off. Wire up the quick disconnect box: note that the red wire on the whip will serve as the neutral. The white wire goes to one line, black to the other. Apply PVC adhesive to the flexible conduit and fittings for a watertight fit. Finally, at the outdoor unit, feed the wires from the whip, cut them to a shorter length, strip the ends, and add appropriate connectors. Connect the green wire to the green ground screw on the right side of the panel, the red/white wire to the neutral terminal, and the black wire to the load terminal. Once all connections are made and verified, close the electrical panel covers.

927.7K views16.3K
MRCOOL

19K subscribers

View Channel

FAQs

How difficult is a DIY air conditioner installation, and how long should I expect it to take?

This is an intermediate-level project, primarily due to the specialized skills required for electrical and refrigerant line connections. While the estimated time is 3 days, actual duration can vary significantly based on your experience and unforeseen challenges. It's often recommended to hire professionals for critical steps like refrigerant handling and electrical hookups.

Is it safe and legal for a DIYer to evacuate and charge refrigerant lines?

Handling refrigerants like R410A requires specialized tools such as a vacuum pump and manifold gauges, and improper handling can lead to environmental damage and system failure. Many jurisdictions require EPA certification for refrigerant work, and it is highly recommended to hire a licensed HVAC professional for these specific steps to ensure safety, compliance, and optimal system performance.

Beyond basic hand tools, what specialized equipment is absolutely necessary for this AC installation?

In addition to tools like a drill and wrenches, you will need a Milwaukee ratcheting pipe cutter for the VEVOR line set, a vacuum pump for system evacuation, and manifold gauges for accurate refrigerant charging and leak testing. A torque wrench is also crucial for tightening flare nuts to the manufacturer's specifications to prevent refrigerant leaks.

What are the most common mistakes when running and connecting refrigerant lines, and how can I avoid leaks?

Common mistakes include improper flaring of copper lines, inadequate tightening of flare nuts, and not thoroughly evacuating the system. Ensure your flares are clean, smooth, and free of burrs, use a torque wrench for precise tightening of connections, and perform a proper vacuum pull and leak test with manifold gauges to prevent refrigerant loss.

Transcript
Hide

these lines that came with the Della are pre-flared so in an effort to not cut and flare the lines I coiled up the excess behind the unit before attaching them to the machine you'll see later that I ended up going back and modifying these lines for a neater install the process is the same here with adding the nylog blue straightening up the flare with the fittings and torquing to the recommended torque settings next we'll be hooking up the electrical I had a set of these black connectors from a previous project where I built a heat treating oven and one of them was the perfect size for connecting the cables that are running from the inside unit to the condenser you want a watertight connection here with whatever connector you decide to use like the inside unit the outside unit is very easy to wire up the cables are labeled along with the ports on the panel the green and ground wire goes to the green ground screw on the left side of the panel the yellow wire goes to port number one the white wire to port number two and the black wire to port number three on the power side I hit the easy button and bought a six foot 10 American wire gauge whip that was pre-made I verified that the 20 amp breaker was turned off and then wired up my quick disconnect box note that the red wire on the whip will be used as a neutral I didn't show it here but I used PVC adhesive on the flexible conduit and fittings to ensure a water tight fit over at the unit I fed the wires in from the whip cut them to a shorter length strip them and then added some connectors to the ends this side the panel is super simple you attach your green wire to the green ground screw on the right side of the panel your red or white wire to the neutral and the black wire to the load after that you can put the panel cover on and you're done with the electrical I made sure to insert the Quick Connect crossbar in the off orientation while I continue on with the install for an added level of safety

Auto-generated transcript. May contain errors.