Check Defrost System (Evaporator Coils and Thermostat) — Defrost System Check

Intermediate6 hours

Part of project

Refrigerator Repair · Step 9 of 10

Helpful?

In this video

To inspect the internal cooling components, open the freezer door. Before proceeding, ensure the refrigerator is unplugged from the wall to prevent injury. Remove any shelves inside the freezer compartment. You will need to remove between four and six screws that secure the thin metal piece covering the evaporator coils. If you encounter a significant amount of snow or ice built up on the back of this panel or on the coils themselves, it indicates a problem with the defrost system. Look for the defrost thermostat and the freezer sensor (also called a defrost sensor) at the top of the evaporator coils. A swollen defrost thermostat unit is a clear sign it's faulty and needs to be replaced. For a more precise test, a technician can check the thermostat's continuity when cooled below 30 degrees Fahrenheit.

7.0M views81.2K
Appliance Helpers

11K subscribers

View Channel

FAQs

What is the most critical safety precaution I must take before attempting any refrigerator repair?

Always unplug the refrigerator from its power source before starting any inspection or repair, even for simple tasks like cleaning condenser coils. This prevents serious electrical shock and ensures your safety throughout the process.

Is a multimeter truly necessary for basic refrigerator troubleshooting, or can I skip it to save on tools?

A multimeter is highly recommended and almost essential for accurately diagnosing electrical components like fan motors, thermostats, and start relays. It helps confirm if a part is faulty, preventing unnecessary purchases and ensuring you address the correct problem.

My refrigerator isn't cooling properly. What are some common DIY fixes for this, and what's their difficulty level?

Often, cooling issues are due to dirty condenser coils or a malfunctioning evaporator or condenser fan. Cleaning coils is an intermediate DIY task, crucial for efficiency. Testing and replacing a fan motor, also intermediate, requires careful handling of electrical connections.

The project suggests an estimated time of 6 hours. Does this include diagnosing the problem, or just the hands-on repair work?

The 6-hour estimate typically covers both diagnosing common issues and performing the subsequent repair. Be prepared to allocate sufficient time for initial checks, component testing, and potential trips for parts if replacements are needed.

Transcript
Hide

or get it repaired now we are going to open up the freezer side door of this refrigerator at this point you'll definitely want the electricity off for safety but we may want to use it to test apart in a little bit with the shelves out we want to investigate defroster system and the evaporator fan next and both can be inspected at nearly the same time you'll need to remove between four and six screws to get the thin metal piece off that covers up the evaporator coils that are responsible for the cooling the whole system down if in the process of this you're fighting a lot of snow or ice buildup on the back of the panel then it's extremely likely you have a defroster problem that needs addressed once you open the evaporator panel you will see the evaporator coils which make the refrigerator cold if this panel has a large amount of ice you want to inspect the defrost thermostat and the defrost sensor at the top of the evaporator coils here's a better view of these components because they're kind of hidden on these types of refrigerators underneath the coils at the bottom of the refrigerator you will find the defrost heater which is designed to turn on every few hours and thaw out the ice and if you have ice then one of these components isn't working to test the heater you'll take a multimeter and set it to ohm's resistance or continuity to see if you can get an electrical signal these ge defrost heaters are very difficult to inspect on the refrigerator itself which is why i'm testing it away from the refrigerator with the two leads check for continuity you should get a signal and with ohm's resistance you're looking for value between 20 and 40 ohms which is good this heater tests good but i noticed that one of the gaskets protecting the heater was bad and could lead to issues so i decided to replace it to be safe anyway going back to the defrost thermostat this little item is another likely culprit to cause the defraud system to not work properly the easiest way to test it is just visually inspect it this is what they look like both good and bad if the lid of the unit seems swollen then you want to definitely replace the defrost thermostat with the kind of model your refrigerator takes now if it's not swollen you can test it by checking for continuity when the thermostat is under 30 degrees this is a little difficult so you may want to call a tech to do this