Determine Staircase Dimensions — Step 1: Count Every Step (Landings, Too!)
Part of project
Landing Measurement · Step 1 of 4
In this video
Before cutting, ensure the stair location has a flat, solid landing base. Accurate measurements are crucial for planning and material costs. When constructing in the framing stage, remember to factor in the thickness of the finished flooring (e.g., hardwood, tile) to prevent the bottom step from being too tall and non-code compliant. First, measure the total vertical rise from the top floor to the bottom floor. For this example, the rise is 85 inches. Next, estimate the number of steps by dividing the total rise by an estimated riser height (typically between 7 and 7 3/4 inches maximum, per code). Round up any uneven result to the nearest whole number to get the total number of steps. In this example, 85 inches divided by 7 3/4 inches (estimated) equals 10.96, which rounds up to 11 steps. Then, calculate the exact riser height by dividing the total rise (85 inches) by the total number of steps (11), resulting in an exact riser height of 7 3/4 inches. Finally, determine the total horizontal run of the staircase by multiplying the number of steps by the required tread depth (at least 10 inches deep, per code). For 11 steps, this yields a total run of 110 inches. The total length of the stringer board needed can then be estimated by multiplying the number of steps by 14 inches (a general rule of thumb), which comes out to 154 inches for 11 steps.
659K subscribers
FAQs
What's the biggest challenge when measuring a U-shaped landing compared to a straight staircase?
The main challenge is accurately capturing the irregular angles and varying depths, especially in the corners where treads meet. U-shaped landings often have non-90-degree corners or sections that aren't perfectly symmetrical, requiring individual measurement of each segment rather than assuming uniformity. Always measure each distinct section of the landing independently.
Are there any specific tools that make measuring a U-shaped landing easier?
While a tape measure and pencil are essential, a carpenter's square or a digital angle finder can greatly improve accuracy for capturing corner angles. For complex or slightly curved edges, creating a template with cardboard or construction paper can ensure a perfect fit for your new treads. A flexible tape measure can also be helpful for irregular curves.
How precise do my measurements need to be for a good fit on a U-shaped landing?
Precision is crucial; aim for measurements accurate to within 1/16th of an inch. Even minor discrepancies can result in noticeable gaps, an ill-fitting tread, or difficulties during installation. Always double-check your figures and consider measuring critical sections from multiple points to confirm accuracy.
How do I account for the 'reveal' when measuring for a U-shaped landing, especially in the corners?
The 'reveal' is the overhang of the tread past the riser, and it should be consistent across all steps and the landing for a professional finish. When measuring your landing, decide on your desired reveal and ensure you consistently add this to the depth measurement along all exposed edges, including where the landing meets the last step tread. This maintains a uniform visual line.
TranscriptHide
Auto-generated transcript. May contain errors.
Determine Staircase Dimensions — Step 1: Count Every Step (Landings, Too!)
Part of project
Landing Measurement · Step 1 of 4
In this video
Before cutting, ensure the stair location has a flat, solid landing base. Accurate measurements are crucial for planning and material costs. When constructing in the framing stage, remember to factor in the thickness of the finished flooring (e.g., hardwood, tile) to prevent the bottom step from being too tall and non-code compliant. First, measure the total vertical rise from the top floor to the bottom floor. For this example, the rise is 85 inches. Next, estimate the number of steps by dividing the total rise by an estimated riser height (typically between 7 and 7 3/4 inches maximum, per code). Round up any uneven result to the nearest whole number to get the total number of steps. In this example, 85 inches divided by 7 3/4 inches (estimated) equals 10.96, which rounds up to 11 steps. Then, calculate the exact riser height by dividing the total rise (85 inches) by the total number of steps (11), resulting in an exact riser height of 7 3/4 inches. Finally, determine the total horizontal run of the staircase by multiplying the number of steps by the required tread depth (at least 10 inches deep, per code). For 11 steps, this yields a total run of 110 inches. The total length of the stringer board needed can then be estimated by multiplying the number of steps by 14 inches (a general rule of thumb), which comes out to 154 inches for 11 steps.
Frequently Asked Questions
What's the biggest challenge when measuring a U-shaped landing compared to a straight staircase?
The main challenge is accurately capturing the irregular angles and varying depths, especially in the corners where treads meet. U-shaped landings often have non-90-degree corners or sections that aren't perfectly symmetrical, requiring individual measurement of each segment rather than assuming uniformity. Always measure each distinct section of the landing independently.
Are there any specific tools that make measuring a U-shaped landing easier?
While a tape measure and pencil are essential, a carpenter's square or a digital angle finder can greatly improve accuracy for capturing corner angles. For complex or slightly curved edges, creating a template with cardboard or construction paper can ensure a perfect fit for your new treads. A flexible tape measure can also be helpful for irregular curves.
How precise do my measurements need to be for a good fit on a U-shaped landing?
Precision is crucial; aim for measurements accurate to within 1/16th of an inch. Even minor discrepancies can result in noticeable gaps, an ill-fitting tread, or difficulties during installation. Always double-check your figures and consider measuring critical sections from multiple points to confirm accuracy.
How do I account for the 'reveal' when measuring for a U-shaped landing, especially in the corners?
The 'reveal' is the overhang of the tread past the riser, and it should be consistent across all steps and the landing for a professional finish. When measuring your landing, decide on your desired reveal and ensure you consistently add this to the depth measurement along all exposed edges, including where the landing meets the last step tread. This maintains a uniform visual line.
Video Transcript